SmartManufacturingSmart Manufacturing connects buyers with smart factory integrators, robotics workcells, MES/SCADA systems, IIoT platforms, vision inspection lines, and intralogistics automation solutions.
315A 4-Pole ATS Automation Control Cabinet for Three-Phase Four-Wire Systems
Factory Automation Planning

315A 4-Pole ATS Automation Control Cabinet for Th | RFQ Sourcing Details

Factory Automation Planning · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryFactory Automation Planning
Unitset
ModelPA-ATS-4P
SystemThree-phase four-wire dual-power transfer system
MountingFloor-mounted or wall-mounted
StructureFixed board;all-packaged
Power factor0.8–0.95 lagging
Busbar systemCopper bar (TMY)
CategoryFactory Automation Planning
AvailabilityInquiry required
Source date2026-07-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Factory Automation Planning. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Product overview This 315A 4-pole automatic transfer switch (ATS) control cabinet is intended for low-voltage, three-phase four-wire power systems that require transfer between two power sources.

The listed internal configuration includes a 4-pole moulded-case circuit breaker, a dual-power transfer controller, three-phase voltage and current meters, a voltage change-over switch, copper busbars, dedicated wiring terminals, panel instruments, and indicator lights.

Supported configuration The cabinet is identified as model PA-ATS-4P and uses a fixed-board, all-packaged structure. Published electrical data includes AC 380/220 V at 50 Hz, 660 V rated insulation voltage, and a 0.8–0.95 lagging power-factor range.

Listed short-time withstand-current options are 16, 25, 31.5, and 50 kA. Overload and short-circuit protection are specified, while the also lists overvoltage, undervoltage, and phase-loss protection. Manual operation is supported, with electric operation offered as an option.

The enclosure is customizable and may be configured for floor or wall mounting. Published enclosure information includes a 1.5–2.0 mm cabinet-material thickness and selectable IP30–IP66 protection grades. The stated operating limits are -10°C to +40°C and an altitude of no more than 2,000 m.

Intended use The cabinet is presented for industrial facilities, factories, buildings, and new-energy installations.

The source description also identifies factory production lines, automation equipment, commercial buildings, data centers, communication base stations, hospitals, mines, oil fields, tunnels, and temporary construction sites as potential scenarios.

Suitability for any particular installation must be established through project-specific electrical and environmental review.

Buyer confirmation checklist Before procurement, confirm the required single-line diagram, actual load current, source arrangement, transfer sequence, fault-current level, neutral-switching requirement, and protection coordination.

Buyers should also verify the final enclosure dimensions, ingress-protection grade, mounting method, cabinet material and thickness, component brands, terminal layout, cable-entry direction, metering arrangement, and whether electric operation is required.

Request documented confirmation of the exact 315A configuration because the general published current-option list contains other ratings.

Confirm the applicable voltage and frequency, short-time withstand rating, transfer time, controller logic, interlocks, protective functions, and whether the installation requires uninterrupted or open-transition operation.

Certification applicability, inspection documents, wiring drawings, factory test records, installation requirements, spare parts, and warranty coverage should also be agreed for the ordered configuration.

315A | Applications and Buyer Notes

315A is organized as a sourcing-ready Factory Automation Planning reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Factory Automation PlanningBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Model
PA-ATS-4PBased on visible page data; confirm exact value in the RFQ.
System
Three-phase four-wire dual-power transfer systemBased on visible page data; confirm exact value in the RFQ.
Mounting
Floor-mounted or wall-mountedBased on visible page data; confirm exact value in the RFQ.
Structure
Fixed board;all-packagedBased on visible page data; confirm exact value in the RFQ.
Power factor
0.8–0.95 laggingBased on visible page data; confirm exact value in the RFQ.
Busbar system
Copper bar (TMY)Based on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryFactory Automation Planning
Unitset
ModelPA-ATS-4P
SystemThree-phase four-wire dual-power transfer system
MountingFloor-mounted or wall-mounted
StructureFixed board;all-packaged
Power factor0.8–0.95 lagging
Busbar systemCopper bar (TMY)
CustomizationAvailable
Rated voltageAC 380V/220V, 50Hz
Operating modesManual;electric operation optional
Protection gradeCustomizable from IP30 to IP66
Operating temperature10°C to +40°C
Rated insulation voltage660V
Cabinet material thickness1.5–2.0mm
Short-time withstand current16kA, 25kA, 31.5kA, or 50kA

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

Smart Manufacturing related sourcing paths

Related categories Smart Manufacturing related paths
Related applications Smart Manufacturing related paths
Related solutions Smart Manufacturing related paths

Smart Manufacturing related product samples

Supplier profile

Smart Manufacturing Imported Supplier Pool
主营:Production Line Retrofit

View full profile >